A biosafety cabinet is Ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined biosafety level. Airflow is drawn around the operator into the front grille of the cabinet, which provides personnel protection. Because cabinet air has passed through the exhaust HEPA filter, it is contaminant-free (environmental protection). The purpose is to maintain the sterility of materials kept inside the chamber and process the chemicals.
What is a BSL?
Biological Safety Level (BSL) is a biocontainment designation developed by the American Biological Safety Association (ABSA) to protect personnel from exposure to harmful, potentially pathogenic microbes in a research or manufacturing environment.
Â
What differentiates BSL designations from one another?
In the United States, the Center for Disease Control specified four general Biosafety Levels, adopted from the ABSA designations. Each increasing BSL corresponds to greater risk, building upon the previous level to provide greater protection.
Which Bio Safety Cabinet is appropriate to which BSL?
Biological safety cabinets were designed to provide localized protection from potentially biohazardous substances. In general, the BSL level corresponds to BSC class, indicating the BSC type most appropriate for each BSL application. The National Science Foundation designates three classes for BSCs:
BSCs, BSLs, and ISO Classes
When it comes to working with hazardous or potentially infectious material, protecting personnel must be the primary concern. However, offering personnel protection does not have to come at the cost of risking product integrity. Class II BSCs provide protection to both personnel and product simultaneously. They provide an ISO class 5 clean environment for product manipulation while ensuring that exhaust air is filtered and ducted out of the environment. Thus, a class II BSC is the ideal solution when working with moderately hazardous material and both personnel and product safety are required
Protect your research and your team’s safety with Brinda Pharma’s Biosafety Cabinets – the leading Bio Safety Cabinet manufacturer of high-quality, durable and reliable Biosafety Cabinets in India. Contact us today to learn more and ensure the safety of your lab!
Model | Class | Internal Dimensions (W X D X H) mm | External Dimensions (W X D X H) mm | Construction |
---|---|---|---|---|
BSC-I-1270-650-S | Class I | 1270 X 650 X 660 | 1420 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-I-1870-650-S | Class I | 1870 X 650 X 660 | 2020 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-A1-1270-650-S | Class II-A1 | 1270 X 650 X 660 | 1420 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-A1-1870-650-S | Class II-A1 | 1870 X 650 X 660 | 2020 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-A2-1270-650-S | Class II-A2 | 1270 X 650 X 660 | 1420 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-A2-1870-650-S | Class II-A2 | 1870 X 650 X 660 | 2020 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-B1-1270-650-S | Class II-B1 | 1270 X 650 X 660 | 1420 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-B1-1870-650-S | Class II-B1 | 1870 X 650 X 660 | 2020 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-B2-1270-650-S | Class II-B2 | 1270 X 650 X 660 | 1420 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-II-B2-1870-650-S | Class II-B2 | 1870 X 650 X 660 | 2020 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-III-1270-650-S | Class III | 1270 X 650 X 660 | 1420 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
BSC-III-1870-650-S | Class III | 1870 X 650 X 660 | 2020 X 750 X 2160 | External G.I. Powder Coated Internal S.S. 316 |
We at Brinda Pharma are committed to fulfilling the needs of our clients; that’s why we do 100% customization based on your needs.
For complete Customization, We follow the standard practice of understanding the URS – User Requirement Specification. Even if you don’t have URS, our experienced Sales Team can guide you to make one or choose one from the Industry Standards.
All Ceiling Suspended Laminar Air Flow comes with the following: